Unless tighter tolerances are specified, the following apply.
Bending Tolerances | |
---|---|
Cranks Stirrups and Ties < 200mm | +0, -5mm |
Cranks Stirrups and Ties ≥ 200mm | +0, -10mm |
Other steel | +0, -15mm |
Length of straight bars | +0, -15mm |
Straight bars where fitment is not critical... | +20mm |
SOURCE
AS/NZS Standards documentation