Tolerances for bars and mesh not used as a fitment | |
---|---|
≤ 600mm | -25, ±0 |
> 600mm | -40, ±0 |
Tolerances for bars and mesh used as a fitment | |
---|---|
Deformed Bars and Mesh | -15, ±0 |
Plain Round Bars and Wire | -10, ±0 |
Ovearll dimension of a cranked column bar | -0+10 |
For the sawn or machined end of a straight bar intended for use as an end-bearing splice, the angular deviation from square, measured in relation to the end 300 mm, shall be within | 2º |