Australian Bar Bending Tolerances

Tolerances for bars and mesh not used as a fitment
≤ 600mm -25, ±0
> 600mm -40, ±0
Tolerances for bars and mesh used as a fitment
Deformed Bars and Mesh -15, ±0
Plain Round Bars and Wire -10, ±0
Ovearll dimension of a cranked column bar -0+10
For the sawn or machined end of a straight bar intended for use as an end-bearing splice, the angular deviation from square, measured in relation to the end 300 mm, shall be within

 

Source
AS/NZS Standards documentation